Semi-Gloss Zinc Fortified Direct to Metal (DTM) Polyaspartic Finish

Dual Cure 182

Dual Cure 182™ is a patented high performance Direct to Metal coating system engineered to provide excellent exterior durability, adhesion and flexibility. This low-sheen protective coating may be applied to blasted, primed or e-coated surfaces. Dual Cure 182™ is a fast curing coating system and is designed to enhance productivity without the need for heat for drying. Additionally, this zinc-fortified formulation provides moderate corrosion resistance and protection in ISO 12944 (C2-C3) environments5 year. It is highly resistant to fresh and salt water, most chemicals, fumes and spills of mild acids and alkalies.

Features
  • Excellent Color and Gloss Retention
  • Attractive Semi-Gloss Finish
  • Single Coat Application Option
  • Superior Adhesion
  • Flexibility
  • 1-Hr. Dry Time
  • No Heat Cure
  • Good Corrosion Resistance
  • High Abrasion Resistance
Applications
  • Heavy-Duty Machinery
  • Trailers
  • Oil and Gas
  • Containers
  • Implements
  • Exterior Steel
  • Marine
Performance Characteristics
Accelerated Weathering: ASTM D4587

 

2000 Hours

gloss retention >70{d19567d3462d58b7cd2bfc0869a29db3f8b9dbad1091a68d0ebed2355250dc72}

Florida Black Box Exposure12 months minimal loss, excellent color retention
Impact (Direct & Indirect)

ASTM G-14

80 in. lbs.
Chemical Resistance100 MEK Double Rubs*
Flexibility: ISO 1519 / ASTM D522Cylindrical Mandrel 10MM ISO

1520 Cupping 5-7mm

Corrosion Weathering:

ASTM D5894, 8 cycles

Rating 10 per ASTM D714 for blistering; Rating 10 per ASTM D610
Salt Spray: ASTM b-117Direct to Metal Blasted: 1000 Hrs.

*all direct to metal chemical corrosion resistance testing completed on SSPC SP 6 blasted steel panels at a DFT of 6-9 mils

Material Properties
Gloss Level50º Satin Gloss
Density12.74 lbs/gal. (1.51 kg/ltr) mixed
Solids56{d19567d3462d58b7cd2bfc0869a29db3f8b9dbad1091a68d0ebed2355250dc72} mixed
Dry Film Thickness3.0-6.0 mils
Colors AvailableFull Color Spectrum Available
Pot Life25 Minutes Mixed
Theoretical Coverage179 sq.ft./gal. @ 5.0 mils DFT
Practical CoverageAs a guideline for airless spraying on large dimension: 70{d19567d3462d58b7cd2bfc0869a29db3f8b9dbad1091a68d0ebed2355250dc72} of theoretical coverage. For small dimensions: 50{d19567d3462d58b7cd2bfc0869a29db3f8b9dbad1091a68d0ebed2355250dc72}

 

OEM Steel Coating White Paper

Changing Paint Can Be Overwelming

Download our free guide: "Four Key Factors to Consider Before Changing Paint" for a comprehensive framework designed to help with your decesion making process. 